ā
Prescription Required
Rx Solution Set with Duo Vent Spike IV vent Set 104"
The Rx Solution Set with Duo Vent Spike is a veterinary IV administration set designed for accurate and efficient delivery of fluids and medications. At 104" in length, it provides extended reach and flexibility during treatments. The dual vent spike design supports compatibility with various IV fluid containers, ensuring a reliable setup for clinical and hospital use.
Key Details:
-
Strength & Count: 104" IV administration set with dual vent spike.
-
Class: Veterinary IV fluid administration set.
-
Indication: Used to deliver IV fluids and medications during veterinary treatment.
-
Use Only Under Vet Guidance: For veterinary use only. Not for human use.
-
Contraindications/Cautions: Single-use only. Do not reuse or resterilize. Must be handled by trained veterinary professionals.
-
Storage: Store in a cool, dry location. Keep packaging sealed until ready for use.
Keep away from children and other household pets.
This item is not returnable or refundable.
Sold in Qty. of 1 (104" set).
Product type: |
Animal Health & Wellness > Medical Supplies |
Brand: |
Baxter |
Status: |
Available |
Animal type: |
All |
Ingredients: |
See product for details. |
Storage & Disposal: |
Store in a cool, dry place. |
Cautions & Warnings: |
Do not allow air to be trapped in set. Puncturing set components may cause air embolism. Single use only. Do not re-sterilize. Keep out of reach of children. |
Dosage instructions: |
Use aseptic technique. Close regulating clamp (5). If using rigid non-vented container, open vent cap (8) and insert spike (2) downward into container. (If using rigid non-vented container less than 150 mL, fully squeeze and hold drip chamber (3) and do not release until after container is inverted and hung.) If using flexible container, insert spike (2) with vent cap (8) closed. Fill drip chamber (3) to fill line. Open regulating clamp (5). Prime set, purge air. Close regulating clamp (5) until roller meets bottom of frame. Attach male Luer adapter (7) to vascular access device using a firm push and twist motion and then engage the Luer lock collar to prevent accidental disconnection. Swab septum of injection site (6) with antiseptic prior to access. Access injection site (6) with siliconized 18 gauge (or smaller bore) needle. To properly set flow, always close regulating clamp (5) until roller meets bottom of frame, then reopen to establish flow rate. Repeat procedure if adjusting clamp from fully open position. |
Weight: |
0.10 |
Dimension (L x W x H): |
10 x 7 x 3 |
Prescription required: |
YES |